Restaurant equipment repair guides

These guides are for the moment something stops working. Each one explains the likely causes in the order a technician would check them, which checks kitchen staff can do safely and when to stop and call.

There are also guides on how repair bills are built, when to replace instead of repair, how to find a model and serial number and how to get equipment ready for an inspection. For the cost side, start with what restaurant equipment repair costs and what drives it.

Coolers and freezers 4

  • Walk-in cooler not cooling: what is failing and what to check

    A walk-in cooler stops cooling when heat gets in faster than the system removes it. The usual causes are a dirty or blocked condenser, an iced-over evaporator, a failed fan motor, a leaking door gasket, a failed defrost or a refrigerant loss. Condenser and gasket checks are safe; the rest need a technician.

  • Walk-in freezer not freezing: defrost, airflow and cooling faults

    A walk-in freezer that will not freeze is most often a defrost problem: a failed heater, termination sensor or timer lets frost choke the coil. Other causes are a dead evaporator fan, a frozen drain, a warm-air leak at the door, or a weak compressor. Door and stock checks are safe; defrost parts are not.

  • Reach-in refrigerator not cooling: why it runs warm and what to check

    A reach-in refrigerator that runs but stays warm usually has a condenser coil clogged with grease and lint, a leaking door gasket, an evaporator fan that has stopped, or a coil iced over from a failed defrost. Overloading and a hot kitchen make all of these worse. A dead unit can also be a failed start component or controller.

  • Prep table not holding temperature: why the rail runs warm

    A refrigerated prep table fails to hold temperature when the top rail does not get enough cold air: a blocked airflow path, an open lid, overfilled pans, a weak rail fan, a dirty condenser or a bad door gasket on the base. The base can read cold while the pans stay warm, so check the food in the rail.

Ice machines 2

  • Commercial ice machine not making ice: causes and first checks

    Four things stop ice production: the bin control says the bin is full, water is not reaching the evaporator, the refrigeration system cannot reject heat, or the harvest cycle is failing. Check the bin, water valve, filter and condenser airflow first. Compressor, hot gas valve and refrigerant faults need a technician.

  • Ice machine making small, hollow or cloudy ice: what it means

    Small, hollow or cloudy ice means the machine is running but the freeze is wrong. The usual causes are scale on the evaporator, low or uneven water flow, a fouled thickness probe, high incoming water temperature and a spent filter. Minerals in the water cause most of the cloudiness. Low refrigerant needs a technician.

Ovens, fryers and cooking lines 8

  • Commercial fryer not heating: what fails on gas and electric fryers

    A fryer that will not heat has lost one of three things: power or gas, a signal from the thermostat or probe, or a closed safety circuit. On gas units the usual culprits are an open hi-limit, a failed ignition module or a weak pilot. On electric units they are a tripped hi-limit, a bad contactor or burned elements.

  • Fryer pilot won't stay lit: causes on standing-pilot gas fryers

    A standing pilot goes out when the pilot flame is too weak or misplaced to heat the thermocouple or thermopile, or when the safety circuit opens and drops out the gas valve. Dirty pilot orifices, an aged thermopile, an open hi-limit and drafts across the flame are the most common causes.

  • Commercial convection oven not heating: causes on gas and electric ovens

    A convection oven that will not heat has lost fuel or power, a heat call from the thermostat or controller, or a safe path through its safety circuit. Gas ovens fail at the ignition system, gas valve or fan proving. Electric ovens fail at the contactor, elements, sensor or high-limit.

  • Convection oven uneven baking: airflow, calibration and loading

    Uneven baking in a convection oven usually means the air is not moving the way the oven was designed to move it. Worn or dirty blower wheels, a loose or missing baffle, a leaking door, a miscalibrated sensor or a pan load that blocks airflow are the common causes, and loading habits can make any of them worse.

  • Pizza oven not getting hot enough: deck and conveyor causes

    In a deck oven the usual culprits are a failed thermostat or bulb, a dead element or weak burner, a cracked deck, and heat lost through the door. In a conveyor oven look at clogged air fingers, a weak blower, a sensor fault, and a burner that is not lighting.

  • Griddle not heating evenly: why one zone runs hot and another cold

    Uneven griddle heat usually comes from a failed thermostat on one zone, a clogged or weak burner on gas units, an open element on electric units, a warped plate that loses contact with the heat, or grease buildup. Low gas pressure or an off-calibration control can also leave one side cold.

  • Commercial range burner won't light: causes and what to check

    A burner that will not light usually has a blocked port or orifice, a pilot that is out or weak, a failed igniter or spark module, or a gas supply problem. A gas smell means you leave the building first and call the gas utility or 911 from outside. Do not keep trying to light it.

  • Steam table not heating: causes, checks and the 135°F rule

    A steam table stops heating from low water or a closed drain, a thermostat set too low or failed, a burned-out element or loose connection, scale on the element, or a tripped breaker. Food should be held at 135°F or above, so a well that cannot get there is a food safety problem as well as an equipment fault.

Dishwashers 2

  • Commercial dishwasher not draining: causes and what to check

    A commercial dishwasher that will not drain is blocked at the strainer or scrap tray, held up by a stopper or drain valve that is not opening, failing at the drain pump on an undercounter machine, or backed up in the building drain. Clear the trays safely, then check the floor drain. Valve and pump faults need a technician.

  • Commercial dishwasher not sanitizing: temperature and ppm causes

    A high-temperature machine fails to sanitize when the final rinse is too cold, usually from a failed booster heater element, a thermostat or a low-pressure rinse. A low-temperature machine fails when the chemical feed is empty, worn or blocked. Check the gauges and test strips first, then call.

Espresso and beverage 1

  • Espresso machine not reaching pressure: what is wrong and who fixes it

    Brew pressure comes from the pump pushing water against the resistance of the coffee puck. Low pressure means the pump is starved of water, the pump is worn, a pressure valve is leaking, or the grind offers no resistance. Check water supply and grind first, then call for a pump and valve test.

Hoods and ventilation 1

  • Kitchen hood not exhausting: belts, fans, filters and make-up air

    A hood stops pulling for four main reasons: the fan is not turning at speed (broken belt, failed motor, tripped overload), the filters are loaded with grease, the duct is restricted, or the kitchen has no make-up air and is starved. A safe first check is the hood switch, the breaker and the filters.

Cost, planning and upkeep 6

  • What decides the cost of a restaurant equipment repair

    The bill follows the part that failed, how hard the equipment is to reach, whether the failure damaged other components, the age and model of the unit, how long the part takes to arrive, and how many hours the visit runs. On site we diagnose first, then give you a written price to approve before work starts.

  • Repair or replace restaurant equipment: how to decide

    Restaurant equipment is worth repairing when the failure is a single wear part and the rest is sound. Replace it when the failure is structural or in the sealed system of an old unit, when the same machine keeps failing in different places, when parts are gone, or when an ENERGY STAR replacement would cut energy and water use meaningfully.

  • Restaurant equipment maintenance schedule: daily to quarterly

    Staff handle daily and weekly work such as gaskets, temperature logs, filters and surface cleaning. Monthly checks cover condensers, drains and sanitizer gear. Technicians take over quarterly or twice a year for ice machine descaling, refrigeration, burner and electrical checks. Always follow the manufacturer's manual where it sets an interval.

  • Health inspection equipment checklist for Minnesota kitchens

    Inspectors look at cold and hot holding equipment and its thermometers, dish machine temperatures and sanitizer strength, door seals and equipment condition, food-contact surface cleanliness, ice machine drains and bins, and hood filters and drip control. Each item traces to the Minnesota Food Code (Minn. Rules chapter 4626), which is built on the FDA Food Code.

  • Equipment down during service: the first hour

    When key equipment fails during service, a kitchen should write down the time of the failure, protect cold and hot food first, then re-plan the menu around what still works. Keep cooler doors shut, move high-risk food to units holding temperature, and call for service with the model, the symptom and any display code in hand.

  • How to find the model and serial number on commercial kitchen equipment

    Every commercial unit carries a data plate, usually metal or a printed label, listing model, serial, voltage and ratings. Look inside the cabinet or door frame, or on the back or side, without opening any electrical or control cover. Photograph it with a phone, then read the digits from the picture.