Commercial range burner won't light: causes and what to check

Open burner on a commercial range will not light or keeps going out? Pilot, port, ignition and gas supply causes, plus what to do safely.

Short answer

Why won't a burner on my commercial range light?

A burner that will not light usually has a blocked port or orifice, a pilot that is out or weak, a failed igniter or spark module, or a gas supply problem. A gas smell means you leave the building first and call the gas utility or 911 from outside. Do not keep trying to light it.

What should you do first if a burner will not light?

Safety comes before diagnosis. If you smell gas, do not operate switches, lighters or phones inside. Leave the building, then call the gas utility or 911 from outside. Do not go back in to look for the cause, and do not wait to see if it clears.

If there is no gas smell, shut the burner control off and wait several minutes so any unburned gas that built up can clear before anyone goes near the burner. Gas that collects in an oven cavity or under a burner can flash when it is lit. Repeated attempts to light a stubborn burner make that risk worse, so do not keep trying to light it. If there is no gas smell and the manufacturer's lighting instructions are posted on the range, staff trained on that range may follow those instructions once; if the pilot does not light or does not stay lit, stop and call.

The rest of this guide helps you describe the problem and know what is safe to check. Anything that involves the gas valve, regulator, manifold or piping on the supply side is a technician job, and the meter and utility piping belong to the gas utility. For the wider picture on gas-fired equipment, see our commercial cooking equipment repair overview.

Why would a burner fail to light on a range with pilots?

Many commercial open-top ranges, including long-running Southbend and similar heavy-duty lines, use a small pilot flame at each burner or a shared pilot. When the pilot is out, the burner will not light from a cold control. The pilot goes out because of a draft, a boil-over, a clogged pilot orifice, a worn pilot tube or low gas pressure.

A pilot that burns weak and yellow, or that flickers and dies, often has a dirty orifice or air restriction. Grease dripping from a hot pot can run down into the pilot area and foul it, which is why the burner next to a fryer or stockpot is usually the first to give trouble. If the pilot stays lit but the burner will not light when the control is opened, the fault is in the valve, the burner path or the air mix, and that moves the job to the technician.

A pilot that is out is not a routine job for staff, and nobody should force a control or hold a flame to the burner to bypass the pilot. If there is no gas smell and the manufacturer's lighting instructions are posted on the range, staff trained on that range may follow those instructions once; if the pilot does not light or does not stay lit, stop and call.

What if the burner uses electronic ignition?

Some ranges, and many newer ovens, use a spark or a glow igniter instead of a standing pilot. A spark module clicks and the burner should light within a few seconds. If you hear clicking but no flame, the spark is not reaching the gas, the gas is not arriving, or the burner ports are blocked. If there is no click, the module, the electrode or the supply to it has failed, and a loose or corroded connection is a common cause.

A hot-surface igniter that glows but the burner does not fire has a different set of causes, including a weak igniter that does not reach temperature and a gas valve that is not opening. Both situations send you to a technician, because testing them means live circuits and gas valve operation.

Whatever the type, note what you see and hear: clicking or silence, glow or no glow, flame color, and whether the issue is one burner or all of them. That description saves time on the call. Our commercial range repair page describes how we work through these faults.

Could the burner itself be dirty or blocked?

Often it is. Burner ports are small, and boil-overs, grease and flour dust bake into them and block the flame path. A burner with blocked ports lights in one place, burns unevenly or will not carry flame around the ring. The orifice that meters gas into the burner can also clog, which starves the burner.

With the range cold and the controls off, lift the grates and the burner head (or cap, where the range has one) and look for caked debris and food in the ports. A stiff nylon brush and a cleaning pick used gently can clear the ports. Do not enlarge the ports with drills or wire, and do not let water stand in the burner or the pilot area. Let everything dry before the range is used again.

A burner head or cap that has been put back crooked is also a surprisingly common cause. If it does not sit flat and centered, the gas and air mix incorrectly and the flame lifts, pops or goes out.

Which burner symptom needs a technician?

Gas smell, pilot trouble and weak flames are not equal risks. The table shows which ones you can handle at a cold burner and which are a call.

What happensLikely causeWho fixes it
Smell of gas around the rangeLeak or unburned gasLeave; gas utility or 911 from outside
Pilot is out on one burnerDraft, spill, dirty pilot orificeTechnician
Pilot lit, burner will not lightValve, air mix, or blocked burner pathTechnician
Clicking, no flameGas not reaching burner, blocked ports, weak sparkTechnician; operator can clean cold burner head
No click and no flameFailed spark module, electrode or connectionTechnician
Yellow, lazy or uneven flameDirty ports, air shutter out of adjustmentOperator cleans cold burner; technician adjusts air
Every burner weak or slowLow gas pressure or supply restrictionTechnician; gas utility if the problem is at the meter

When is it the building's gas supply?

If every burner is weak, or several gas appliances on the same line are slow at the same time, look beyond the range. A partly closed shutoff, a kinked flex connector after the range was moved, or a regulator problem can all reduce pressure. Gas piping and the utility side of the meter are not our work, and they belong to a gas contractor or the gas utility.

A technician can measure pressure at the range manifold with the other equipment running to see whether the supply holds up under load. That reading tells you whether the fault sits in the range or in the line feeding it. When the oven or griddle on the same line has similar trouble, see our griddle not heating evenly guide for what low pressure looks like on a flat top.

A safe sequence to follow

  1. Check for gas odor

    Gas odor at any point: walk out of the building, then call the gas utility or 911 from outside. Do not continue.

  2. Turn the control off and wait

    Shut the burner off and give any gas several minutes to clear before anyone goes near the burner again.

  3. Inspect the cold burner

    With the range cold, lift the grate and the burner head (or cap, where the range has one) and look for food, grease and blocked ports. Reseat it flat.

  4. Let it dry

    If you cleaned with any liquid, let the burner and pilot area dry fully before the range is used again.

  5. Leave the relight to us

    Keep the burner controls off and call. Only with no gas smell and the manufacturer's instructions posted on the range may trained staff follow them once.

When to stop and call

  • Gas smell near the burners: leave the building, then call the gas utility or 911 from outside.
  • A pilot is out or will not stay lit.
  • The pilot stays lit but the burner will not light.
  • You hear clicking with no flame, or you hear no click at all.
  • More than one burner is weak or the flames are yellow, tall or popping.

Questions about this problem

Why does the burner next to the fryer keep going out?

A burner next to the fryer keeps going out because heat, grease and drafts concentrate at the edge of a line. Grease can drip into the pilot area, and air pulled by a hood or a fryer flue can blow a small flame out. Cleaning the cold burner and pilot area helps, but a pilot that keeps failing needs a technician to check the pilot orifice, pilot tube and supply pressure.

Is it safe to relight a range pilot myself?

Only if there is no gas smell and the manufacturer's lighting instructions are posted on the range, and then only staff trained on that range, following those instructions once. If the pilot does not light or does not stay lit, stop and call. Never bypass a safety or hold a flame to the burner.

Can I use a drill bit to open clogged burner ports?

No, you should not use a drill bit on clogged burner ports, because enlarging ports changes the gas and air mix and can cause tall, unstable flames or flashback. Clear ports with a soft nylon brush or a cleaning pick sized for the opening, with the range cold. If the ports are damaged or corroded, the burner is replaced.

What does clicking with no flame on a range mean?

Clicking with no flame on a range means the ignition spark is firing but the burner is not catching. Common causes are gas that is not reaching the burner, blocked burner ports, a dirty or misaligned electrode, or a valve that is not opening. Because it can involve live circuits and gas valves, report it to a technician.