Independent on-site repair of Avantco refrigerators, bar coolers, fryers and griddles in Minneapolis, Saint Paul and the metro.

  • Brand ownerClark Associates (sold via WebstaurantStore)
  • Retailer headquartersLititz, Pennsylvania
  • Lines we repairReach-ins, bar coolers, fryers, griddles
  • Where the tag isCabinet interior or back, frame side on cooking units
Short answer

What breaks on Avantco coolers, fryers and griddles?

Avantco refrigerators fail mostly at fans, condensers, gaskets and controllers, while fryers and griddles fail at thermostats, gas valves, pilots, igniters and burners. Because Avantco is sold mostly through web retailers, owners often have no local dealer to call, so an independent technician is often the first stop.

Avantco reach-in refrigerators, bar coolers and fryers

Avantco is an exclusive brand of the Clark Associates group of Lancaster County, Pennsylvania, sold mainly through its online retailer WebstaurantStore. Its refrigeration line includes reach-in refrigerators and freezers, beer dispensers, bottle coolers and glass chillers, and its cooking equipment includes electric and gas floor fryers and gas griddles. Owners are often new operators, food trucks, bars and small cafes that bought the unit online at an entry-level price and had it delivered to the door.

That purchasing path defines the repair situation. There is often no local dealer who sold, installed and services the unit, so the first call is often to an independent technician, and the warranty paperwork lives with the seller. We identify the model, check the warranty document that came with it and tell you what is likely to be involved. Our commercial fryer repair and reach-in refrigerator repair pages describe how those jobs go.

Reading the plate on Avantco reach-in refrigerator

Avantco units carry a rating plate with the model, serial number, voltage and, on gas equipment, the gas type and BTU rating. On refrigerators it is typically inside the cabinet or on the back panel, and on fryers and griddles it is on the side or rear of the frame. Keep the retailer order and the warranty document handy too, as they identify the exact model.

Avantco reach-in refrigerators and freezers

Seen on this line: Cabinet jammed against a wall with no airflow / Door not closing on its own / Fan stalled or noisy / Controller reading wrong

Avantco reach-ins are common in small restaurants and bars that need affordable storage. The faults match other reach-ins: condenser fans and evaporator fans that stop, coils clogged with dust, gaskets that tear and controllers that misread. Because these cabinets are often installed by the owner, we also see placement problems, such as units tight against a wall with no airflow, or leveled badly so the door does not close on its own. We check the install before the parts, since a cabinet jammed into a hot corner will struggle regardless of component condition. Parts for Avantco refrigeration are sold through the retailer's own catalog, which helps with ordering.

Avantco beer dispensers, bottle coolers and glass chillers

Seen on this line: Foamy beer at the tap / Keg freezing at the back / Sliding door worn at the track / Glass chiller coil icing heavily

Avantco's bar equipment includes direct-draw beer dispensers, bottle coolers and glass chillers, which are sold to taprooms, bars and event venues. Keg dispensers fail like any direct-draw cooler: a weak compressor or blocked coil produces foamy pours, a failing fan lets the temperature climb, and a faulty thermostat can freeze the keg. Bottle coolers have sliding or hinged doors that wear at the track and seal. Glass chillers run very cold, so their evaporators frost heavily, and a defrost or control problem shows quickly. We confirm the tap temperature and the cabinet temperature, and check the gasket and track seal, since a poor seal masks everything else.

Avantco electric and gas floor fryers

Seen on this line: Pilot or igniter will not stay on / Oil does not reach set temperature / High-limit trips repeatedly / Burner flame uneven or yellow

Avantco's floor fryers are the line's cooking workhorse, in both electric and gas versions. On gas models the common calls are pilot or igniter faults, a thermostat or high-limit that trips, a burner that is dirty or burning unevenly, and a gas valve that does not open. Electric models fail at heating elements, contactors, thermostats and the high-limit. In both, oil that has not been filtered clings to the controls, and a thermostat that reads wrong causes oil that runs too hot or never reaches temperature. Gas valves, gas piping and wiring are technician work, so if you smell gas, leave and call from outside.

Avantco gas griddles

Seen on this line: Hot and cold zones across the plate / Burner lights unevenly / Pilot goes out / Thermostat does not hold setpoint

Avantco's gas griddles use burners under a steel plate, with manual or thermostatic controls. The calls we get are burners that light unevenly, a plate that runs hot over the burners and cool in between, pilots that go out and thermostats that no longer hold the setting. A plate warped by thermal shock or heavy scraping creates hot and cold zones that no control adjustment will fix. Drip trays and grease paths also clog and affect combustion air. We inspect the burners, the pilot, the valve and the plate flatness, and we describe whether the fault is a part or the plate itself. Gas connections and valves are for a technician only.

Sourcing parts for Avantco griddle

Avantco parts are sold largely through WebstaurantStore's own parts catalog, which lists replacement parts for its refrigeration line, and some universal parts have generic equivalents. Because the cabinets and fryers are built for a private label, a given part may differ from similar-looking items sold under other names, so matching by model number is important. We confirm the part number and where it comes from before the repair is approved, and we do not promise stock or speed.

More Avantco equipment: freezers and prep tables

Questions about Avantco equipment

Why does my Avantco electric fryer trip its high-limit and go cold?

An Avantco electric fryer trips its high-limit and goes cold when the oil overheated, from a thermostat that reads wrong or a heating element or contactor that stays energized. The high-limit is a safety device, so never bypass it. Let the oil cool, check the oil level and call.

Why does my Avantco glass chiller ice up inside?

An Avantco glass chiller ices up inside because glass chillers run near or below freezing, so a door that does not seal or a defrost fault builds ice quickly. Check that the door closes and the gasket lies flat, and keep glasses off the back wall. If the ice returns, the defrost or control needs testing.

Why will my Avantco fryer not stay lit?

An Avantco gas fryer that will not stay lit has a pilot or igniter problem, a dirty thermocouple or a gas valve fault. These involve gas, so do not try to adjust them yourself. A gas smell at the fryer means you walk out of the building first, then call the gas utility or 911 from outside.

Is the Avantco griddle plate supposed to have hot spots?

Some difference between zones on an Avantco griddle plate is normal near the burners, but large swings point to a warped plate or burners that are lighting unevenly. A flat plate and clean, even burner flames are the goal. A technician can inspect both.

My Avantco bottle cooler is freezing the beer. What should I check?

An Avantco bottle cooler freezes beer when the setpoint is too low, bottles are pressed against the back wall where the evaporator is, or a probe or thermostat is out of range. Check the setpoint and the bottle position first. If the setting is right and it still freezes, the control needs testing.