Open 24/7, 365 days a yearMinneapolis & St. Paul, MNCommercial Only
Call 24/7(612) 429-3465

Charbroiler, salamander and cheesemelter repair in Minneapolis and St. Paul

On-site charbroiler, salamander and cheesemelter repair in Minneapolis and St. Paul: burners, radiants, igniters, pilots and flare-up problems.

Short answer

Why is my charbroiler heating unevenly or flaring up?

An uneven charbroiler usually has a blocked burner or venturi tube, a collapsed or cracked radiant, or a pilot that is weak. Flare-ups come from grease built up on the radiants and in the pan below. A technician tests each burner, clears the airflow and replaces failed radiants.

How a charbroiler fails and gets repaired

A charbroiler works on radiant heat from the burners below the grate, and a salamander or cheesemelter works on radiant heat from above. Both are simple machines that suffer from grease, heat and constant cleaning. One dead burner leaves a line cook shuffling steaks to a hot lane, and a flare-up in the middle of service is a fire risk. We repair gas and electric charbroilers, salamanders and cheesemelters on site.

Charbroilers make smoke and grease vapor that rely on the kitchen's exhaust, so a weak hood can mimic an equipment problem. If the real problem is the exhaust fan rather than the broiler, the hood and ventilation service side covers that, and the rest of the line starts at commercial cooking equipment repair. Burners, radiants and pilots are tested one lane at a time, so a cold lane is traced to the part that failed instead of the whole set being replaced.

Charbroiler complaints, causes and corrections

What the charbroiler is doing, why, and the repair
ComplaintLikely causeCorrection
One lane or section runs coldA burner blocked by grease or debris, a clogged venturi tube, or a burner that is not lighting from its neighbor.The technician cleans the burner and venturi, checks the crossover lighting and replaces a burner that has rusted through.
Flare-ups and flames licking the foodGrease saturating the radiants or briquettes, or a pan below that is full.The technician replaces saturated radiants or briquettes, cleans the pan and baffles, and checks the burners are not set too high for the load.
Burner flame is yellow and lazyIncomplete mixing of gas and air because a venturi is partly blocked or the air shutter is closed too far.The technician clears the venturi and ports and sets the air shutter for a steady blue flame.
Pilot will not stay litA weak thermocouple, a blocked pilot orifice, or grease dripping onto the pilot.The technician cleans the pilot assembly, tests thermocouple output and shields the pilot from drips.
Burners click but do not light on an igniter modelA cracked electrode, carbon on the spark gap, or a failed module.The technician inspects the igniter, cleans or replaces the electrode and tests the module.
Salamander only heats on one sideA failed ceramic tile, a clogged port in the burner, or a damaged burner end.The technician replaces the cracked tile or burner section and clears the ports.
Radiants burned through or collapsedYears of heat and grease acid wear out the metal.The technician replaces the full set of radiants rather than one, so the heat is even across the grate.
Electric charbroiler elements do not heatAn open element, a bad infinite switch or a loose terminal.The technician tests each element and switch, then replaces the part that has failed.
Heavy smoke and poor draw above the unitA grease-loaded broiler, a weak exhaust fan or a hood filter that is full.The technician cleans the broiler thoroughly and tests hood airflow; fan and make-up air problems belong to ventilation service.

Before you call about a charbroiler

  • With the unit off and cool, empty and reseat the grease pan and drip tray. A full pan is both a fire risk and a cause of flare-ups.
  • Look at the grate and radiants cool for broken, collapsed or heavily greased sections and note where cold lanes appear.
  • On an electric unit, make sure the breaker feeding the elements has not tripped. Reset it once; if it trips again, leave it off and call.
  • Confirm the exhaust hood fan is running before you fire the unit.
  • If the charbroiler area smells of gas, leave the building and call the gas utility or 911 from outside. Never hold a flame to a burner to light it.

Stop at gas valves, 208, 240 or 480 volt wiring, sealed refrigerant circuits, steam under pressure and anything live. Those are a call.

How we diagnose a charbroiler

  1. Light and watch each burner

    The technician fires the unit and watches the lighting sequence, flame color and crossover from lane to lane.

  2. Inspect radiants, briquettes or tiles

    The heat-spreading material is checked for collapse, cracks and grease saturation, because it affects both heat and flare-ups.

  3. Clean and test the burner path

    Burner ports and venturi tubes are cleared, then flame quality is rechecked with the air shutter set correctly.

  4. Test pilot and ignition parts

    Pilot flame, thermocouple output, igniters and spark modules are tested, with the technician handling gas and live circuits.

  5. Check airflow and surroundings

    Hood draw and the grease path are looked at so the repair is not undone by the exhaust or a full pan.

Parts that fail most on charbroilers and salamanders

Radiants
Metal plates over the burners that spread heat and catch grease; they burn through over time.
Burner tube and venturi
Mixes gas and air; clogs from grease and food spills.
Pilot assembly and thermocouple
Keeps the gas valve open; blocks with grease and weakens with age.
Ceramic tile or burner head
On infrared and salamander units, the glowing surface that gives intense heat; cracks from thermal shock.
Igniter and spark module
Lights the burner on electronic-ignition models; gets fouled by grease and carbon.
Gas valve
Controls flow to the burners and the gas to each lane; can stick or leak.
Electric element and switch
On electric units, the heating strip and the control that meters it.

Charbroilers and salamanders we repair, by type

  • Radiant charbroiler

    Metal radiants sit over the burners and spread heat to the grate. Collapsed radiants and blocked burners cause cold lanes.

  • Lava rock or ceramic briquette charbroiler

    A bed of rock or briquettes holds heat and takes grease. When the bed saturates, it flares and has to be changed.

  • Infrared or ceramic-tile broiler

    Ceramic tiles heated by a gas flame give very high surface heat. Cracked tiles and blocked ports are typical faults.

  • Salamander

    An overhead broiler on a shelf or riser, often with an adjustable rack. Pilot, igniter and gas valve problems dominate.

  • Cheesemelter

    A smaller overhead unit used to melt and finish, usually without the movable rack of a salamander. Burner and pilot faults are similar.

  • Electric charbroiler or salamander

    Elements, switches and contactors instead of gas parts. Open elements and bad switches are the faults.

What decides the cost

Repair or replace the charbroiler?

Charbroilers wear out in predictable pieces. Burners, radiants, igniters, valves and pilots are all replaceable, and a well-kept unit lasts for many seasons. Replacement is the better path when the body has rusted through, the frame has warped from heat, or parts for the model are no longer sold. Because grease fire is the risk, a unit that has had repeated flare-ups and damage deserves an honest look. Our repair-or-replace guide covers how to weigh it against the cost of a new broiler.

Charbroilers and salamanders by brand

Related to charbroiler repair

Where we repair charbroilers and salamanders

Every city we serve, by county

Other cooking equipment repairs

Questions about charbroilers and salamanders

What is the difference between a salamander and a cheesemelter?

A salamander and a cheesemelter are both overhead broilers. A salamander is usually the stronger unit, often with a rack that adjusts height, for finishing and browning. A cheesemelter is generally a smaller, simpler unit used to melt, and the repair work on both is similar in practice.

Why does my charbroiler flare up so much?

A charbroiler flares up when grease reaches the flame. Saturated radiants or briquettes, a full pan, or burners turned too high for fatty items all contribute, and cleaning plus replacing worn radiants usually helps. Hood airflow and burner height also affect how much flame reaches the food.

How often should radiants be replaced?

Charbroiler radiants have no set replacement date, because they wear with use. Replace them when they are burned through, collapsed, or when heat is visibly uneven. Replacing the whole set evens out the cooking surface and avoids the one-bad-lane problem you get when only one radiant is changed.

Can I use water to put out a charbroiler flare-up?

No, water should not be used to put out a charbroiler flare-up, because water hitting hot grease can spatter and spread burning grease. Follow your fire safety training and call emergency services if a fire is not immediately controlled. The fire suppression system over the line is serviced by the fire protection company that maintains it, not by us.

Why does my cheesemelter take a long time to heat?

A cheesemelter heats slowly when a weak flame comes from a clogged port, a cracked burner tile or a pilot that is not lighting the whole burner. A technician checks each in turn, starting with the pilot and the burner ports, before replacing any tile.

Does an electric charbroiler need different repair?

Yes, an electric charbroiler needs different repair. Instead of burners and pilots, you have elements, infinite switches and contactors. Failures are open elements, burned switches and loose terminals, tested with the unit isolated by the technician, since these run on high-amperage circuits that you should not open.

Call 24/7

Call with the model and what it is doing

You hear the earliest opening on the phone. After the diagnosis you get a written price to approve before any repair starts.

Call (612) 429-3465