Koolaire ice machine repair in the Twin Cities

On-site Koolaire KT-series ice machine repair in Minneapolis, Saint Paul and the metro: safety limit lights, float switches and remote units.

  • Owner companyManitowoc Ice, owned by Pentair
  • Lines we repairKT cube machines (KDT, KYT), Kubers, undercounter
  • Refrigerant on KT seriesR410A (the T in the model number)
  • Safety limitsSL#1 and SL#2 lights on the control board
Short answer

What do the SL lights on a Koolaire ice machine mean?

On KT-series Koolaire machines the control board lights name the safety limits. SL#1 is freeze cycles running the full 60 minutes, and SL#2 is harvests running the full 3.5 minutes. Safety limit 3, the harvest float switch not opening after the water inlet valve energizes, has no light of its own: SL#1 and SL#2 flash together.

Koolaire ice machines

Koolaire's own website is branded Koolaire by Manitowoc Ice, with product pages for Kubers, undercounter machines, bins and accessories. Manitowoc Ice was sold by Welbilt to Pentair, a deal that closed on July 28, 2022, so the control boards and manuals now come from that business, and the shared design is why the checks follow a set order. The KT series covers dice and half-dice cube machines from the 300 to the 1700 size, as self-contained air-cooled, self-contained water-cooled and remote air-cooled models.

Koolaire machines sit under bar counters, in prep areas and in back hallways where the bin is filled all day. They share a design family with Manitowoc ice machines, so the checks are familiar, but the board, the lights and the timers are written out in Koolaire's own handbook and a technician reads them in that order. For ice machines in general, see ice machine repair; the KT handbook's own details follow below.

Reading the plate on Koolaire ice machine

The manual points to the ice machine model and serial plate and says the serial tag overrides other data for electrical ratings. Read the model number with its parts: K, then D for dice or Y for half-dice, then T, the capacity such as 0420 or 1000, and A for air-cooled, W for water-cooled or N for remote. Keep the model, serial number and the SL light pattern on the control board on hand for the call.

Koolaire KT cube machines and the freeze and harvest cycle

Equipment guide

Ice Machine Repair

Seen on this line: Thick or double slab after a power cycle / Harvest never starts after the water leaves the float / Cycles into harvest too early / Machine idle with the curtain light showing a full bin

A KT machine makes a sheet of cubes on a vertical evaporator. It purges the water trough, pre-chills the evaporator, then freezes until the ice thickness float switch tells the control board to harvest, and the sheet slides into the bin and past the water curtain. The board locks the machine into freeze for 6 minutes before it will allow a harvest, caps freeze at 60 minutes and caps harvest at 3.5 minutes. The handbook warns that starting a new freeze with ice still on the evaporator, for example after power was cycled or the curtain was opened mid-harvest, makes a thick or double slab, so clear the evaporator before any diagnosis. A water curtain that is held open or a bin switch that is defective reads as a full bin.

Koolaire safety limits, board fuse and test mode

Equipment guide

Ice Machine Repair

Seen on this line: SL#1 flashing on long freeze cycles / SL#2 climbing from slow harvest / SL#1 and SL#2 flashing together, machine waiting 30 minutes / Board dead with no curtain light

Safety limits are stored and shown by the control board. After three 60-minute freezes in a row SL#1 flashes, and six stop the machine with SL#1 steady. Three 3.5-minute harvests in a row flash SL#2, the light stays on after 75, and a hundred stop the machine. Safety limit 3 has no light of its own: SL#1 and SL#2 flash together when the harvest float switch has not opened within four minutes of the inlet valve energizing, and the machine waits 30 minutes before restarting on its own, stopping after 100 in a row. Cycling the toggle switch off and on clears the stored limit. The board has a 250 V, 3.15 amp fuse, and a lit curtain light with the curtain closed means it is good. A technician can run the board's two-minute test mode, which energizes the relays on a board that carries line voltage at all times.

Koolaire KT remote and water-cooled models

Equipment guide

Ice Machine Repair

Seen on this line: High discharge pressure on a water-cooled model / Remote condenser located beyond the line-set limits / Harvest pressure regulating system not holding / Low water pressure starving the inlet valve

KT1000N and KT1700N remote machines depend on the line set and condenser location: the condenser may sit at most 35 feet above the machine or 15 feet below it, and the calculated line length may not exceed 150 feet, otherwise oil return to the compressor suffers. Remote condensers add a harvest pressure regulating system. Water-cooled KT models need entering water no warmer than 90°F, flow no higher than 5 gallons per minute and leaving water no warmer than 110°F, with the water regulator valve holding discharge pressure. The handbook's discharge-pressure analysis assumes you record the air or water temperatures first, since a high reading from a dirty condenser and one from a failed regulator valve look alike on the gauge.

Descaling and sanitizing a Koolaire KT

Seen on this line: Scale on the evaporator and float switch / Curtain or distribution tube not cleaned / Wrong cleaner used on the machine / Water distribution tube not split and soaked

The KT handbook says to descale and sanitize every six months, and sooner where water quality demands it, with the maker's own descaler and sanitizer only. A full cleaning means taking the water curtain off and splitting the water distribution tube into its two pieces so the solution reaches the evaporator and the parts soak. A preventative maintenance descale runs the machine's own cycle to clean the water path between those visits without removing the ice. Scale on the evaporator and a sticky float switch are what a machine nobody has cleaned usually shows.

Koolaire fault codes by equipment

EquipmentCodeMeaning
Ice Machine RepairSL#1Safety limit 1: freeze cycle reached 60 minutes. Flashes after 3 in a row, steady and machine stopped after 6.
Ice Machine RepairSL#2Safety limit 2: harvest reached 3.5 minutes. Flashes after 3 in a row, stays on after 75, and the machine stops after 100.
Ice Machine RepairSL#1 + SL#2 flashingSafety limit 3: harvest float switch not opened within 4 minutes of the inlet valve energizing; the machine waits 30 minutes and restarts, and stops after 100 in a row.

Sourcing parts for Koolaire ice machine

KT parts follow the model and serial number, and the handbook lists non-OEM components among the causes of safety limit faults, so refrigeration parts are matched to the charge and the R410A on the plate. Control boards, float switches, the water curtain and bin switch and the harvest valve are Koolaire-specific. Pumps, fan motors and contactors are verified against the electrical data before one is fitted.

Koolaire next to Manitowoc and Scotsman

Questions about Koolaire equipment

Why does my Koolaire sit idle with ice in the bin?

The water curtain acts as the bin switch. If ice holds it open, the machine shuts off and restarts at the water purge when the curtain closes. A curtain that is stuck, or a defective bin switch, can falsely show a full bin. Check that the curtain swings freely and the bin is not packed against it.

Does a Koolaire safety limit mean a failed part?

Not by itself. A limit is the board reporting a pattern, such as freezes that ran long or harvests that never cleared the curtain. It still needs the cause found: water, scale, a float switch, the harvest valve or refrigerant. Cycling the toggle switch only clears the stored limit.

What does the second letter in a KDT or KYT model mean?

In the KT series the first letters give the cube: D is dice and Y is half-dice. The T marks the R410A refrigerant, the number is the capacity, and the last letter shows air-cooled, water-cooled or remote. KYT1000N, for example, is a half-dice 1000 size remote machine.

How often does a Koolaire need descaling?

The KT handbook says every six months at minimum, and more often if the water calls for it. It names the maker's descaler and sanitizer as the only approved products. Hard water, a dirty condenser and a cloudy float switch all show up first as long freeze cycles.

Can a Koolaire condenser be placed anywhere on the roof?

Not anywhere. On the remote models the maximum rise is 35 feet, the maximum drop is 15 feet and the calculated line-set length is limited to 150 feet. Beyond those figures oil return and compressor starting suffer, and the machine can show up as repeated freeze faults.