Short answer

Why is my display case warm or fogging up?

A display case that runs warm or fogs up usually has a worn door gasket, a failed anti-sweat heater, a dirty condenser, a stopped evaporator fan or a failed defrost cycle. Check the food temperature with a probe. Fogging on the glass points at moisture getting in or at a dead door heater.

How a display case fails and gets repaired

A display case has a job no other cooler has: it must show the product and hold temperature with glass between the two, in a room full of customers. That glass, the lights above it and the customers touching the door create most of its failures. We repair service deli cases, bakery cases, grab-and-go merchandisers and glass-door coolers on site, without asking you to empty the cabinet unless the repair requires it.

Display problems usually appear as a customer-facing complaint first: fogged glass, wet product, a shelf that feels warm to the touch or a light that has flickered out. The cause may be a simple gasket or a cooling fault, and the answer depends on whether the case is self-contained or served by a remote condensing unit. If your case holds frozen product, see commercial freezer repair for the freezer side. For tables on the line that hold cold product open, see prep table repair.

Display case complaints, causes and corrections

What the display case is doing, why, and the repair
ComplaintLikely causeCorrection
Glass fogs or drips in humid weatherA door heater has failed, a gasket is no longer sealing, or the case is sitting in humid air with the doors opened often.We test the heater and the gasket and replace what is open or worn. We also look at the room humidity around the case.
Product feels warm on the shelvesThe evaporator fan has stopped, the coil is iced, the air curtain is blocked or the compressor is not pulling down.We measure air at the discharge and return, clear the air path and repair or replace the fan, heater or sensor that failed.
Ice on the coil or on the rear wall of the caseA defrost heater, sensor or timer is down, or the drain has plugged and meltwater is refreezing.We test each defrost part and replace the one that failed. The drain is cleared first, then the coil is thawed, so the meltwater has somewhere to go.
Water under the case or in the drain panThe drain line is plugged, the pan has cracked or an evaporator pan is overflowing.We clear the line, check slope and replace the pan or hose if it has failed.
Lights flicker or failAn LED strip, a driver or a connector has failed. Lights heat a case, so a dead light is not always bad news, but customers notice.We replace the strip or driver and confirm the connectors are dry and secure.
Compressor runs constantly and the case never catches upA clogged condenser, a failed fan or an overloaded air curtain makes the case work too hard.We clean the condenser, test the fans and check how product is placed in front of the air return.
Doors drift open or do not seatA hinge, closer or magnet is worn, or the cabinet is not level. The gasket never seals if the door never closes.We adjust the cabinet level, replace the hinge or closer and confirm the gasket compresses all the way around.
Temperature alarm without warm productA probe has drifted, a connector has corroded or a controller is reading the coil. The case is fine and the display is wrong.We compare against a calibrated thermometer and replace the probe, harness or controller as the test shows.

Before you call about a display case

  • Probe the food itself, not the air, and note which shelf is warm.
  • Check that product is not stacked above the load line or blocking the air return or the air curtain in an open case.
  • Look at the door gasket for tears and wipe it clean with warm water and mild soap. Close the door fully and check that it stays shut.
  • Clear the condenser grille of boxes and dust, with the case unplugged, using a dry soft brush.
  • Do not spray water or glass cleaner on the lights or into the case fan area, and wipe the glass only after the heater has had time to warm it.

Stop at gas valves, 208, 240 or 480 volt wiring, sealed refrigerant circuits, steam under pressure and anything live. Those are a call.

How we diagnose a display case

  1. Probe product and read the case

    We measure food temperature, discharge air and return air. The difference tells us whether the case is moving air properly.

  2. Inspect doors, glass and heaters

    Gasket compression, door alignment and anti-sweat heater continuity explain most fogging complaints.

  3. Check the evaporator, fans and drain

    We look at frost patterns, test fan motors and flow-test the drain line. These faults are the quiet cause of warm shelves.

  4. Test defrost and controls

    Timer, heater, termination sensor and controller are tested individually.

  5. Separate case from unit on remote systems

    On remote-condensing cases we compare case-side readings with the condensing unit before any refrigerant circuit is opened, which federal law requires EPA Section 608 certification to do.

Parts that fail most on display cases

Door gaskets and magnets
Seal the case. A gasket that no longer compresses brings in humid air that fogs glass and frosts the coil.
Anti-sweat door heater
Warms the glass frame to keep condensation off. When it fails, the glass fogs first.
Evaporator fan motor
Moves cold air through the case. Bearings wear in a damp, cold environment.
LED strips and drivers
Light the product and add a small heat load. Moisture is the usual cause of failure.
Defrost heater, timer and sensor
Keep the coil clear. A failure here shows up as a slow build of ice and warm shelves.
Condensate drain pan and hose
Carry meltwater away. Debris and product wrappers plug them.
Door hinges, closers and track
Keep doors square and closing. Glass doors are heavy and wear their hardware.

Display cases we repair, by type

  • Service deli and meat cases

    Curved or straight glass with a rear sliding door. Condensation on the glass and drip pans that clog are the usual service calls.

  • Bakery cases, refrigerated and dry

    Refrigerated bakery cases hold cream and custard product at 41°F or below. Dry, non-refrigerated cases share the glass and lights but have no refrigeration to repair.

  • Glass-door merchandisers

    Upright coolers with one to three glass doors. Door heaters, gaskets and LED lighting fail first.

  • Grab-and-go open and semi-open cases

    An air curtain holds cold air in an open front. A dirty or blocked air curtain warms product quickly.

  • Countertop and refrigerated display cases

    Compact cases for dessert, deli or beverages on a counter. The condenser is often tucked into a tight space.

  • Remote-condensing cases

    Refrigeration is supplied from a unit elsewhere in the building. The diagnosis separates case-side faults from unit-side faults.

What decides the cost

Repair or replace the display case?

Display cases are the part of the refrigeration system customers see, so appearance counts alongside function. Repair is right for gaskets, heaters, fans, lights, controllers and defrost parts. Replacement becomes the better choice when the front glass is damaged and out of production, the base is corroded or the sealed system has failed on an older case. The repair or replace guide shows how to compare a repair with a new case.

Display cases by brand

Related to display case repair

Where we repair display cases

Every city we serve, by county

Other refrigeration repairs

Questions about display cases

Why does the glass on my deli case fog in the morning?

Moist air meets glass that is colder than the room's dew point. A failed anti-sweat heater, a gasket that leaks or a door left open for stocking is the usual cause. A room with the dish area or a kitchen door open nearby makes it worse.

Should I pull product out of the case while it waits for repair?

Yes, product that needs 41°F holding should leave a failing display case for a working cooler once a probe shows it above that. The glass front and lights add heat, so a failing case warms faster than a closed cabinet. Probe each shelf separately, because the air reading can look fine while one shelf is warm.

Is it okay to cover the top shelf with cloth or paper?

No, you should not cover the top shelf of a display case with cloth or paper, because covering the evaporator discharge or the air return blocks the air the case needs. Product on the shelf should also stay clear of the rear air return. Misplaced liners are a common reason one shelf warms while the rest stays cold.

Do open grab-and-go cases need different service?

Yes, open grab-and-go cases need different service because an open front relies on an air curtain, a stream of cold air across the opening. A blocked curtain, a dirty honeycomb or a weak fan lets warm air in. The fix is airflow and coil work, not just a lower setpoint.

What causes water to run out of the bottom of the case?

Water runs out of the bottom of a display case when defrost meltwater has nowhere to go. The drain line or pan is plugged, the case is out of level, or the coil is icing and overflowing the pan. Clearing the drain is a fast repair; ignoring it floods the floor and rots the base.

Can a bakery case be run as a refrigerated case?

No, a dry bakery case cannot be run as a refrigerated case unless it is built for that. Dry bakery cases are not refrigerated, so they cannot hold cream or custard product at 41°F; only a refrigerated bakery case can. Putting that product in a dry case is a food-safety problem, not a repair problem.