Heatcraft, Bohn and Larkin refrigeration repair in the Twin Cities

Repair for Heatcraft, Bohn and Larkin unit coolers, condensing units and controls on walk-ins and reach-ins in Minneapolis, St. Paul and nearby.

  • OwnerLennox International Inc. (Heatcraft Refrigeration Products segment)
  • HeadquartersStone Mountain, Georgia (Heatcraft Refrigeration Products)
  • Lines we repairWalk-in and reach-in unit coolers, condensing units, controls
  • Where the tag isSerial data tag; wiring diagram inside panel door
Short answer

What fails most often on Heatcraft, Bohn and Larkin refrigeration equipment?

Most calls trace to the defrost circuit: a worn defrost termination thermostat, a fan delay control that no longer holds the fans off, a burned-out defrost heater or a frozen drain line. Heatcraft's own troubleshooting chart lists those causes for iced coils, ice in the drain pan and fans that will not start.

Heatcraft (Bohn, Larkin) walk-in coolers, walk-in freezers and reach-in refrigerators

Heatcraft Refrigeration Products is a business segment of Lennox International, based in Stone Mountain, Georgia. Its brand list includes Bohn, Larkin and Climate Control, plus the intelliGen controller and the InterLink parts program. You rarely see the name on a restaurant's front door. You see it on the evaporator hanging from the ceiling of a walk-in cooler, on the condensing unit on the roof or the wall outside, and on the thin coil tucked into the top of a reach-in.

That matters for repair, because the box can carry one maker's name while the cooling system inside carries another's. A walk-in built by Kolpak or Nor-Lake may be cooled by a Bohn or Larkin coil, and the failure is then in the coil and its defrost controls, not the panels. We work from the plate on the coil or condensing unit, and the problems we see are tied to how these particular products defrost, drain and start up.

Reading the plate on Heatcraft (Bohn, Larkin) walk-in cooler

Heatcraft's manual says the serial data tag on a unit cooler carries the unit's electrical characteristics, and that the wiring diagram is located inside the electrical panel door. On most coils and condensing units you can read the model, serial number, voltage and phase from that tag. Read the tag, the refrigerant and the fixture name aloud when you call. Tell us whether the coil says Bohn, Larkin or Heatcraft, because the box maker's name will not match.

Heatcraft, Bohn and Larkin walk-in unit coolers

Equipment guide

Walk-In Cooler Repair

Seen on this line: Fans do not restart after a defrost because the coil never gets cold enough to reset the thermostat / Frost building on the ceiling and fan guards from a defrost that runs too long or an unset fan delay / Uneven frosting from a missing or wrong distributor nozzle, or a failed heater element

Heatcraft lists walk-in unit coolers as low profile, low velocity center mount, center mount and medium profile. Its installation manual publishes a troubleshooting chart, and the first symptoms on it are the ones we are called for: fans that will not run, ice building on the ceiling and fan guards around the coil, and a coil that does not clear during defrost. The listed causes include a defective defrost thermostat or timer, too long a defrost, and a fan delay that is not holding the fans off after defrost. Uneven frosting is attributed to a defective heater, a unit placed too close to a door, a low termination setting, or an incorrect or missing distributor nozzle. For ice on the ceiling and fan guards, the chart's remedy is a manually started defrost and a check of the defrost controls.

Electric defrost and drain lines on Heatcraft freezer coils

Equipment guide

Walk-In Freezer Repair

Seen on this line: Ice accumulating in the drain pan from a dead heater, a plugged line or an unheated trap / Drain line heater that has failed or was never wired to run continuously / Defrost timer fail-safe cutting a heater cycle short, leaving the coil half-cleared

A freezer coil is where the manual's drain instructions matter most. Heatcraft requires every condensate line to be trapped, pitched a minimum of a quarter inch per foot and run to an open drain, never straight into the sewer. Traps must sit in a warm space, and outdoor traps and long outside runs need a drain line heater that runs continuously. The manual gives 20 watts per linear foot for a 0°F room and 30 watts per linear foot for a minus 20°F room, and says the drain pan fitting inside a freezer should be heated and insulated as well. When a freezer coil floods the floor or ices the pan, the dead drain heater or a trap in a cold spot is the usual finding. Defrost is timed with a fail-safe set at the defrost length plus 25 percent.

Heatcraft reach-in coils: TA, TL, C, VA, mullion, back bar and Twin Flow

Seen on this line: Air defrost TA coils that stop clearing frost when the box cycles too short / Fan delay on the TL not holding, so warm air blows before the coil is cold / Mullion and back bar coils with a plugged drain fitting or heater failure

Heatcraft's reach-in guide names its coils by model letters: TA thin profile air defrost, TL thin profile electric defrost, C high profile, VA Vee-Aire, BBM and BBL back bar, KMK Kompact Mullion, RAMK reverse air flow Kompact Mullion, and BTO Twin Flow. The thin profile coils sit in the top of a cabinet, so a failed fan or heater means opening the top of the case. The TL has a fan delay built in so the coil chills before the fans return, and the BBL back bar model uses an Incoloy sheath heater with automatic electric defrost for 0 to minus 10°F fixtures. The mullion coils sit beside the door frame behind tray slides, which shapes how a technician reaches them. The drain fitting on several models is angled at 45 degrees.

Heatcraft condensing units, PRO3 packages and intelliGen controls

Seen on this line: Compressor trips traced back to a coil running at low superheat / Defrost kits and controller settings left at factory defaults after a coil change / Condenser coils choked with dust, grease or cottonwood in the Twin Cities summer

The condensing side runs from 1/2 to 6 HP horizontal air-discharge HTS units through the HCU, VCU and DVCU families, the PRO3 top-mount package, and remote compressor RCU units. Heatcraft also sells the intelliGen refrigeration controller, the Beacon II refrigeration system, a lead-lag temperature controller and the InterLink smart defrost kit. Its manual warns that the unit cooler must be checked for superheat before it is released, because low superheat promotes liquid slugging and compressor damage, while high superheat lowers capacity. A technician therefore reads superheat on the coil as part of any compressor call, not only the high and low side pressures. The sealed system itself is not an operator task.

Sourcing parts for Heatcraft (Bohn, Larkin) refrigeration unit

Heatcraft sells replacement parts through its InterLink program, which it describes as a line of certified commercial refrigeration parts, accessories and electronic controls for all its brands, including Bohn and Larkin. In practice the parts on these calls are defrost termination thermostats, fan delay controls, timers, heater elements, fan motors, distributor nozzles and drain line heaters. A coil that predates the current catalog may map to a replacement model, so we match the tag to the part before ordering.

Heatcraft (Bohn, Larkin) next to Kolpak and Nor-Lake

Questions about Heatcraft (Bohn, Larkin) equipment

Why is there ice around the fan guards on my Bohn evaporator?

Heatcraft's chart lists ice on the ceiling and fan guards as a defrost that runs too long, a fan delay that is not holding the fans, a failed defrost thermostat or timer, or too many defrosts. Do not chip the ice. Call us, because a damaged coil can leak refrigerant.

Does a Larkin coil need a drain line heater in a walk-in freezer?

The Heatcraft manual calls for a drain line heater on traps located outside or on long outside runs, running continuously, and for heating the drain pan fitting in a freezer. It gives 20 watts per foot for 0°F rooms. If the pan keeps icing, the heater is the first thing we test.

What is the fan delay control on a Heatcraft coil?

It holds the evaporator fans off after defrost until the coil is cold again, so water and warm air are not blown into the room. The manual describes it as a thermostat: the fans should restart once the coil control is below about 35°F, and if they do not, the motor and its supply are checked. A failed one leaves fans blowing during defrost or never starting.

Are Heatcraft, Bohn and Larkin the same company?

Heatcraft Refrigeration Products lists Bohn and Larkin among its brands, and Heatcraft is a business segment of Lennox International. The brand name on the cabinet depends on the product line, but the defrost and drain requirements in the installation manual cover the whole family.

What can staff check on a Heatcraft condensing unit before calling?

Only the outside of it, and only from the ground. If the condensing unit sits at ground level or indoors, keep it clear of leaves, lint and grease and check the breaker; never go up on a roof to reach one. The compressor and refrigerant circuit are a technician call, because federal law requires EPA Section 608 certification to open a sealed system. Give us the model off its tag.