What goes wrong most often on a Faema E71 E?

On a Faema E71 E the maker's engineer manual points to group boiler pressure and temperature sensors, a boiler heating timeout caused by a tripped safety thermostat or open element, and a USB power supply fault on the control board. Softener and water-filter messages are often the first warning.

Faema espresso machines

Faema was founded in Milan in 1945 and is best known for the E61 group of 1961. Cimbali Group has owned it since 1995. Two kinds of Faema turn up here: the E61 Legend, named for that 1961 group, and the E71 E, a touchscreen machine with Wi-Fi connectivity and an Economy mode. You find them on the front counters of independent coffee shops, restaurant bars and the lobby cafes of hotels.

Faema documents the E71 E with a use and installation manual and an engineer's manual that holds a table of numbered diagnostic messages, so a technician can read what the machine reported and which group it came from. Operators can wipe the steam wand and run the prompted cleaning, nothing more. That table is why a Faema call starts with the number on the screen. The shared category page is espresso machine repair, and espresso machine no pressure covers a weak extraction.

Reading the plate on Faema espresso machine

On the E71 E the nameplate carries the voltage that must match the electrical and water supply. Look at the front and the back of the machine for the plate. Read us the three-digit diagnostic number on the E71 E screen and the group digit in front of it (group 1 is far left), then the model and serial from the nameplate.

Faema E71 E: boilers, sensors and the control board

Seen on this line: Boiler heating timeout from the safety thermostat or an open resistance / Group boiler temperature or pressure sensor out of range / USB power supply fault on the control card

The E71 E engineer's manual lists numbered diagnostics. Code 052 is a boiler heating timeout of 45 minutes, caused by a tripped safety thermostat, loose or broken fastons, an interrupted boiler resistance or a faulty triac card. Group boiler pressure sensor and group boiler temperature sensor faults carry the group number, counted from the left, and the cure is the cabling first, then the sensor, then the card. Code 020 is a USB power supply fault from a port drawing too much current; the port should recover once the cause is fixed, and if it does not the manual says to replace the CPU board. Page 47 of the same manual also lists code 024, a clock malfunction from oxidised contacts or a dead 3 V battery, the glass fuse on the CPU board, and code 041, milk pump motor overcurrent from a blocked rotor or a faulty pump.

Faema E71 E: water change, softener and cleaning cycles

Seen on this line: Softener or water filter message ignored until scale forms / Cleaning cycle stopped part way so the machine stays locked / Milk system message after a cleaning cycle was skipped

The E71 E is built around prompts. A machine that shows Machine cold, please wait has not yet reached its service boiler pressure, and Service needed, Softener and Change water filter are timers set from the water used. The manual has a Water change cycle for the hot water boiler that drains about 60 to 70 percent of its capacity, to be run at least daily. Washing runs as sequential, simultaneous or single cycles with the maker's detergent, and the screen tells the operator to remove portafilters. Milk-system faults are read from the display with the same group-by-group method.

Faema E61 Legend and older E61 machines still in service

Seen on this line: Group running cold because scale or air blocks the circulation path / Pump noise or low brew pressure on an older machine / Obsolete valve or board that needs a matching part

Faema's E61 Legend takes its name from the 1961 machine. The E61 group is heated by water circulating from the boiler through the group, which keeps the brew head hot without a separate heater. That circulation depends on a clear path, so scale inside the group, an air pocket after a repair or a stuck valve gives a cold group and unstable temperature. Group gaskets, screens and the electric pump are the other regular items. Older machines in service often have parts that are no longer listed, so we match them by plate and by sample.

Faema fault codes by equipment

EquipmentCodeMeaning
Espresso Machine Repair052Boiler heating timeout of 45 minutes per the E71 E engineer's manual: safety thermostat tripped, broken cabling, open boiler resistance or a faulty triac card.
Espresso Machine Repairx21Group boiler x pressure sensor out of range, where x is the group number from 1 to 4 and group 1 is far left. Check cabling, sensor and card.
Espresso Machine Repairx51Group boiler x temperature sensor out of range, with the thermocouple disconnected or the sensor failed.
Espresso Machine Repair020USB power supply malfunction because the port draws too much current; replace the CPU board if it does not recover.
Espresso Machine Repair024Clock malfunction per manual p.47: oxidised contacts or a dead 3 V battery.
Espresso Machine Repair041Milk pump motor overcurrent per manual p.47: blocked rotor or a faulty pump.

Sourcing parts for Faema espresso machine

Faema parts include group boiler pressure and temperature sensors, boiler resistances and safety thermostats, the triac card, the Newton board, milk pump motors, solenoid valves, group gaskets and screens. The manuals name the Service Line detergent range for the washing cycles. We read the model code and group count off the plate before ordering, as versions of the E71 and E71 E differ in their cards.

Faema next to La Marzocco and Nuova Simonelli

Questions about Faema equipment

What does Machine cold, please wait mean on my E71 E?

You pressed a dispensing key before the service boiler reached its set pressure, so the machine blocks the drink. Normal warm-up is expected after switch-on. If the message stays for a long time, a heating timeout, a tripped safety thermostat or an open boiler resistance may be keeping it from heating.

How often should the hot water boiler be changed on a Faema E71 E?

The manual describes a Water change cycle that drains about 60 to 70 percent of the boiler and refills it, and it asks for this at least once a day. The machine prompts for it. Skipped changes let hot water taste flat and let minerals build up faster in the boiler.

A group number is shown with a sensor fault. Which group is group 1?

Group 1 is the group at the far left of the machine, and the numbers run to the right up to group 4. The sensor code carries that number, so the technician knows which group boiler to check without opening every one. Check that group's cabling and sensor before replacing the card.

Is the E61 Legend the same as the 1961 Faema E61?

It takes its name and look from that design and is sold by Faema, which the Cimbali Group has owned since 1995. The group still relies on boiler water circulating through the head to stay hot. Original machines from the 1960s and 1970s may be in use too, and those need parts matched by sample.

Why does my E71 E ask me to change the water filter?