Open 24/7, 365 days a yearMinneapolis & St. Paul, MNCommercial Only
Call 24/7(612) 429-3465

Jet-Tech dishwasher repair in the Twin Cities

On-site repair of Jet-Tech high-temperature undercounter and door-type dishwashers in Minneapolis and St. Paul: air traps and drain pumps.

  • Parent companyMVP Group Corp. (Jet-Tech brand)
  • OfficesFort Lauderdale, Florida and Pointe-Claire, Quebec
  • Lines we repairHigh-temperature undercounter and door-type dishwashers
  • Data plateModel and serial on the plate; read both to us
Short answer

What goes wrong most often on a Jet-Tech dishwasher?

Most Jet-Tech calls trace to the water-level system (the air trap and air pressure switch), the drain pump on drain-pump models, the peristaltic detergent and rinse-aid pumps, or incoming water that is not at the 30 psi flow pressure and 140°F the maker specifies. The wash tank also needs draining daily.

Jet-Tech dishwashers

Jet-Tech is the warewashing brand of MVP Group Corp., which lists offices in Fort Lauderdale, Florida and Pointe-Claire, Quebec. Its catalog is all high-temperature machines: the 737E and EV-18 undercounters, the F-16DP, F-18DP and Defender B-21 undercounters, the EV-22, 757E and 757EV door-type machines, and the Defender F-47 hood-type machine. In the Twin Cities that mostly means small bar and restaurant dish stations where a single undercounter handles the whole dish load.

These machines are built around one rack at a time and a booster-fed rinse that tops up the wash tank every cycle rather than dumping and refilling. That design is why the water-level system, the drain pump and the chemical pumps cause so many calls. The sections below cover what the maker's own manual says to check for each fault. For the general work on any machine of this type, see commercial dishwasher repair.

Reading the plate on Jet-Tech dishwasher

The manual has a line for model, serial and install date on its last page, and the model number is what separates a drain-pump machine from a gravity-drain one. Tell us the model printed on the plate or the front, whether there is a white drain button beside the green power button, and whether the door or a cycle button starts the wash. Read us the rinse gauge reading while it rinses if you can see it, and say what the detergent flow indicators do.

Jet-Tech undercounter machines: 737E, F-16DP and F-18DP

Seen on this line: Constant fill from a dirty air trap, leaking level tube or failed air pressure switch / Drain pump jammed by debris on the impeller, or a restricted drain hose / Will not start: door microswitch, momentary relay, timer or cycle button

The maker's manual for the F-series and 727/737 undercounters ties most faults to the water level. The wash tank fills until an air pressure switch senses the level through a tube from an air trap, so a dirty air trap, a leak in that tube or a weak switch gives constant filling, short filling or a tank that runs low and makes the wash pump draw air. The 727, 737, F-16DP and F-18DP carry a drain pump. When it jams, the usual cause is debris on the impeller or a restricted drain hose behind the unit, and the manual says to expect a drain under a minute. A machine that will not start points to the door microswitch, the momentary relay, the timer or the pressure switch.

Jet-Tech door-type machines: the F-22, 747 and 767 family

Seen on this line: Cycle will not start after the door closes: door switch or timer reset / Slow heat-up to the 185°F booster and 160°F wash targets / Rinse gauge outside 30 psi flow pressure from supply or regulator

On the F-22, 747 and 767 family, closing the door starts the wash cycle, and the cycle light comes on for a few seconds after the door opens to reset the timer. So a door that no longer trips its switch, or a timer that never resets, shows up as a machine that sits ready and does nothing. The same manual gives a working target of about 185°F in the booster and 160°F in the wash tank, reached in roughly fifteen to twenty minutes from a cold fill, and a rinse gauge reading of 30 psi flow pressure. A rinse that reads low or high points to the building water supply or a missing pressure regulator before it points to the machine.

Peristaltic chemical pumps and the clear flow indicators

Seen on this line: Flow indicator does not move during fill or rinse / Squeeze tube worn or perforated, which the maker treats as a wear item / Air in the pump after a container change, needing a prime

Jet-Tech mounts peristaltic detergent and rinse-aid pumps in the base, each with a transparent cylinder and a flow indicator that should move between Min and Max during the initial fill and the rinse. If the indicator sits still, no chemical is moving, and the manual says not to run the machine until that is fixed. The usual causes are an empty or kinked line, a blocked pickup filter on the container end of the tube, air in the pump that needs priming, or a worn squeeze tube inside the pump. A pump whose center roller does not turn at all needs service. Glasses with spots after the rinse often come back to this pump rather than to the water.

Sourcing parts for Jet-Tech dishwasher

Jet-Tech machines use their own air pressure switches, air traps, drain pumps, peristaltic squeeze tubes, door microswitches and timers, and the manual identifies the squeeze tubing and gaskets as wearable items. The model and serial matter because the F-series, 727 to 767 and EV machines differ. Hard water over about 6 grains and unfiltered supply speed up scale on heaters and the level system.

Jet-Tech next to Jackson and Champion

Questions about Jet-Tech equipment

Why does my Jet-Tech keep filling and never stop?

Constant filling on these machines usually means the level system is not reading correctly. The maker's list starts with a tank left sitting for hours, a cracked or burred stand pipe, a faulty air pressure switch, a leak in the tube down to the air trap, or dirt in the air trap itself. Draining and cleaning the tank is the safe first move.

Is the white button on my Jet-Tech a drain button?

On the 727, 737, F-16DP and F-18DP it is. It runs the drain pump with the power off, the door open and the stand pipe pulled. Hold it only until the tank empties. Drainage over a minute points to a blocked impeller or a restricted hose, and debris blockage is a common cause.

Does a Jet-Tech dump the wash water every cycle?

No. The maker says these high-temperature machines refresh the wash water with hot rinse water each cycle and expel only the excess through the overflow. That is why the manual wants the tank drained and cleaned at least daily or when it is soiled, and the machine drained and left empty overnight.

What water does a Jet-Tech need to wash and sanitize properly?

The manual specifies incoming water at 140°F and 30 psi flow pressure, with a pressure reducing valve where the building runs higher. Booster and wash targets are about 185°F and 160°F. Low supply pressure under 20 psi or a closed valve shows up as long fills and poor rinsing.

Why are there spots on glasses from my Jet-Tech?

The maker lists the rinse-aid pump first: it may need priming or adjustment, or the rinse agent may be poor quality. Hard water is the other cause, and the manual suggests having the incoming water analyzed and possibly filtered. Check that the rinse flow indicator moves during the rinse.

Sources

Call 24/7

Call with the model and what it is doing

You hear the earliest opening on the phone. After the diagnosis you get a written price to approve before any repair starts.

Call (612) 429-3465