Metro C5 heated holding cabinet repair in the Twin Cities
Metro C5 heated holding and proofing cabinet repair in Minneapolis and St. Paul: touch controls, elements and blowers. Phone service 24/7.
What fails on a Metro C5 heated cabinet?
On Metro C5 cabinets the repeat failures are the air heater element, the blower, the water level sensor and the touch controller. A 9 Series that blinks Fill with water in the reservoir usually has a scaled sensor or water that is too pure. A cabinet that trips a GFCI after a long idle can have damp elements.
Metro food warmers
Metro, formally InterMetro Industries, was founded in 1929 and is headquartered in Wilkes-Barre, Pennsylvania. The company started with wire shelving and still builds Super Erecta shelving, which we do not repair. Metro is an Ali Group brand, and Ali's brand page names the C5 heated holding and proofing cabinets among its featured products. This page is only about those cabinets, and the shelving, carts and prep stations Metro also builds are outside what we repair.
The C5 line shows up in school and hospital kitchens, caterers, and banquet halls, where hot food is held for service. The family splits into the 9 Series, which controls humidity as well as temperature, and the 8 Series, which controls temperature and treats humidity as an option. Both use a touch-screen controller, a blower and a heater element, and both are covered under food warmer repair. Combination holding and proofing use also touches bakery equipment repair.
Reading the plate on Metro food warmer
Metro puts the data plate on the back of a C5 cabinet. The model number, serial number and electrical rating are printed there, and the manual says to confirm the rating before ordering any electrical part because 120V 2000W, 120V 1440W and 220-240V versions use different parts. The main power switch is also at the back. Read us the model, whether it is a 9 Series or an 8 Series, and the voltage and wattage.
Metro C5 9 Series controlled-humidity cabinets
Equipment guide
Seen on this line: Fill indicator blinking with water in the reservoir / Water sensor probe scaled, loose or missing its bushing / No heat with the element icon lit, low amp draw / Dashes instead of a temperature or humidity reading
The 9 Series carries a reservoir in the cabinet floor holding about 4 gallons, with a heater and a water level sensor. Metro states that the reservoir cover must be installed for the cabinet to work, and that the water level should sit no higher than half an inch below the cover. The controller shows temperature and humidity and goes into Pre-Heat after the start-up sequence. Metro's manual lists a blinking Fill indicator with more than an inch of water as a sign that the water is too pure, as with distilled water, and tells you to add a tablespoon of baking soda. It also says the sensor probe must point vertically down and have its plastic bushing. A temperature display above 220°F points to the blower, its wiring, or a failed thermostat with the thermal overload doing the controlling, and Metro says to stop using the cabinet.
Metro C5 8 Series controlled-temperature cabinets
Equipment guide
Seen on this line: Cabinet draws too few amps with the heat icon on / Temperature display runs hot after a blower or sensor fault / Cabinet trips a GFCI outlet after sitting unused / Dashes on the temperature or humidity display
The 8 Series uses the same touch-screen family but the humidity comes from a pan of about one quart in the floor duct, and the manual says the floor duct and pan must be installed so heat distributes evenly. Menu presets, alarm, auto start and timer settings can be saved to a USB flash drive and loaded back, and the controller firmware can be updated through the USB port. Metro's cabinet manuals give a typical draw check for a no-heat call: roughly 16 amps on a 120V 2000W cabinet, 12 amps on a 120V 1440W cabinet, and 8 to 9 amps on a 220-240V cabinet. A cabinet that draws far less with the element icon lit points to the air heater element, its wiring or the heater relay on the controller.
Sourcing parts for Metro food warmer
Metro's manuals publish replacement part numbers for the controller screen, sound module, blower and elements, and they flag in bold where a part differs by voltage, amps or wattage. The part number key in the manual decodes the cabinet size, door type, slide type and electrical rating. Several parts differ between the 120V and 220-240V versions, so the data plate rating comes first.
Metro next to Alto-Shaam and Hatco
Same owner: Ali Group
Compared with
Questions about Metro equipment
Why does my Metro C5 9 Series keep flashing Fill when the reservoir has water?
Metro's manual gives several causes. The water may be too pure, as distilled water is, and a tablespoon of baking soda in the water fixes that. Otherwise the sensor probe is scaled, loose, not pointing down, missing its plastic bushing, or has a wiring or probe fault. We check the probe first.
My Metro cabinet trips the GFCI after sitting all summer in a school kitchen. Is it broken?
Not necessarily. Metro says heater elements can absorb moisture during a long idle period, such as a summer in a closed school kitchen, and it describes a controlled dry-out run. We do that dry-out and then test the elements and wiring for leakage. Do not keep resetting the GFCI or move the cabinet to an unprotected outlet. Unplug it and call us.
What does a display over 220°F on a Metro C5 mean?
Metro lists the blower wiring, a failed blower, or a failed thermostat with the thermal overload doing the controlling. It tells you to stop using the cabinet immediately. Unplug it, move the food, and call us. Do not keep running a cabinet that is overheating.
Can I fill a Metro 9 Series with distilled water?
Metro says distilled or conditioned water reduces scale, and that you may need to add baking soda for the low water sensor to work properly. It also recommends draining the reservoir at the end of each day so dirty water does not sit overnight, and descaling with a food-grade descaler.
Does Metro say the controls need calibration?
No. Metro's manual states that the temperature and humidity controls do not require field calibration. If the displayed reading looks wrong, the cause is a sensor, a connection in the communication harness, or the controller, and we test those instead of adjusting the set point.